The inlet air temperature of turbines are significantly high which may result in the damage of the blade material. As a consequence, it is required to cool the turbine blades and a number of cooling techniques are introduced in the past. The cooling technique involving evaporation of water droplets is the motivation and focus of this work. When the water droplets are injected along with the dry air, the existing concentration difference between the water droplets and dry air results in the evaporation leading in the drop of the coolant temperature. This phenomena does not occur when the coolant is dry air and this part is addressed for the first time in this study. The cooling performance is investigated on wall of straight channel in the presence of a film cooling hole. Dry air along with water droplets are supplied through the film cooling hole and the computations are carried out for different droplet diameters and mist concentrations. Results showed that, the overall cooling effectiveness is always larger for the mist-air case compared to that for the dry air case. Also, the cooling effectiveness increases with the percentage of mist in the mist-air system for a specific droplet diameter. At a specific mass flow rate and specific mist percentage, the increase in droplet diameter results in the decrease of cooling effectiveness.
Skip Nav Destination
Close
Sign In or Register for Account
ASME 2017 Gas Turbine India Conference
December 7–8, 2017
Bangalore, India
Conference Sponsors:
- International Gas Turbine Institute
ISBN:
978-0-7918-5850-9
PROCEEDINGS PAPER
Computational Study of Film Cooling With Mist and Air for a Flat Plate
Mallikarjuna Rao Pabbi Setty,
Mallikarjuna Rao Pabbi Setty
Indian Institute of Technology Madras, Chennai, India
Search for other works by this author on:
Pratibha Biswal,
Pratibha Biswal
Indian Institute of Technology Madras, Chennai, India
Search for other works by this author on:
Bhamidi Prasad
Bhamidi Prasad
Indian Institute of Technology Madras, Chennai, India
Search for other works by this author on:
Mallikarjuna Rao Pabbi Setty
Indian Institute of Technology Madras, Chennai, India
Pratibha Biswal
Indian Institute of Technology Madras, Chennai, India
Bhamidi Prasad
Indian Institute of Technology Madras, Chennai, India
Paper No:
GTINDIA2017-4549, V001T03A003; 11 pages
Published Online:
February 2, 2018
Citation
Pabbi Setty, MR, Biswal, P, & Prasad, B. "Computational Study of Film Cooling With Mist and Air for a Flat Plate." Proceedings of the ASME 2017 Gas Turbine India Conference. Volume 1: Compressors, Fans and Pumps; Turbines; Heat Transfer; Combustion, Fuels and Emissions. Bangalore, India. December 7–8, 2017. V001T03A003. ASME. https://doi.org/10.1115/GTINDIA2017-4549
Download citation file:
- Ris (Zotero)
- Reference Manager
- EasyBib
- Bookends
- Mendeley
- Papers
- EndNote
- RefWorks
- BibTex
- ProCite
- Medlars
Close
Sign In
29
Views
0
Citations
Related Proceedings Papers
Related Articles
Film-Cooling Effectiveness on a Rotating Turbine Platform Using Pressure Sensitive Paint Technique
J. Turbomach (October,2010)
Effects of a Reacting Cross-Stream on Turbine Film Cooling
J. Eng. Gas Turbines Power (May,2010)
Simulation of Film Cooling Enhancement With Mist Injection
J. Heat Transfer (June,2006)
Related Chapters
Control and Operational Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Introduction
Consensus on Operating Practices for Control of Water and Steam Chemistry in Combined Cycle and Cogeneration
Outlook
Closed-Cycle Gas Turbines: Operating Experience and Future Potential